E43-449 · Transition Fit Selection Error · Packaging cam ø32 with shaft selected H7/js6 transition, should be H7/p6 to maintain phase · ★★
Fretting from the cam transition fit shifted the process phase and caused packaging mis-registration.
[Mechanism] The packaging cam relies on interference to set phase; unstable transition-fit interference frets and causes mis-registration.
[Calculation] Phase shift Δ makes bag position off by δ=π·D·Δθ, δ_min≈0.005mm; js6 can be zero.
[Design Omission] The packaging cam was wrongly given a transition fit; design defect → phase deviation.
1) Change the cam to H7/p6 interference;
2) Add a pin to prevent rotation;
3) Verify against δ_min;
4) Control surface roughness;
5) Press-fit positioning;
6) Select a stable tolerance grade;
7) Phase inspection;
8) First-article phase measured ≤0.5°.
GB/T 1800.2-2020 Geometrical Product Specifications (GPS) — Limits and fits