E43-209 · Geometrical Tolerance Errors · Pressure Vessel Flange DN300, 12 equally spaced holes · ★★★
Bolt hole position Φ0.5mm (allowable Φ0.2) made the mating flange holes interfere during assembly
[Mechanism] Accumulated error of the dividing head and wear of the drilling jig let the hole positions drift.
[Calculation] A position tolerance of Φ0.5 shifted the holes by 0.5 against the 0.2 bolt clearance, so the bolts would not pass.
[Design Omission] No drilling jig was used for location and the position tolerance was not inspected; this design flaw caused the interference.
1) Locate with a drilling jig and keep the division accuracy ≤0.05;
2) Inspect the position tolerance ≤Φ0.2;
3) Drill the mating flange as a matched set;
4) Trial-assemble the first piece;
5) Compensate the accumulated error;
6) Chamfer the holes and deburr;
7) Inspect with thread plug gauges;
8) Bring position tolerance into the mandatory inspection list.
GB/T 1182-2018 Geometrical Tolerances