Excessive Chuck Jaw Mounting Face Runout Causes Workpiece Runout

E43-210 · Geometrical Tolerance Errors · Three-Jaw Chuck ∅250 · ★★

Problem Symptom

Circular runout of the jaw mounting face 0.05mm (allowable 0.02) increased the radial runout of the clamped workpiece

Root Cause

[Mechanism] The runout of the chuck back face and the spindle face was transferred to the jaws.
[Calculation] A circular runout of 0.05 gave a workpiece runout of 0.05 against the 0.02 allowable, so the turned roundness was 2 times worse.
[Design Omission] The chuck back face was not lapped and the runout was not measured; this design flaw caused the increased runout.

Correct Solution

1) Lap the chuck back face against the spindle face;
2) Inspect the circular runout ≤0.02;
3) Match and number the jaws;
4) Turn the soft jaws to self-center;
5) Keep the clamping face clean;
6) Measure the runout in the trial run;
7) Re-lap periodically;
8) Bring runout into the installation inspection.

Checklist

References

GB/T 1182-2018 Geometrical Tolerances