E43-211 · Geometrical Tolerance Errors · Fan Drive Shaft ∅70×1200 · ★★
Total runout 0.08mm (allowable 0.03) made dynamic balancing impossible and caused vibration
[Mechanism] The eccentricity of each section combined with bending added up to the total runout.
[Calculation] A total runout of 0.08 shifted the center of mass by 0.04, and the residual unbalance exceeded G6.3.
[Design Omission] The shaft was not straightened and the total runout was not inspected; this design flaw made balancing impossible.
1) Straighten the shaft to a total runout ≤0.03;
2) Unify the datum on the two center holes;
3) Rough and finish turn in one setup;
4) Dynamically balance to G6.3;
5) Inspect the total runout;
6) Remove material and add counterweights;
7) Run unloaded to check the vibration;
8) Bring total runout into the process specification.
GB/T 1182-2018 Geometrical Tolerances