Excessive Measuring Platform Flatness Causes Measurement Errors

E43-228 · Geometrical Tolerance Errors · CMM Platform 800×1200 · ★★

Problem Symptom

Platform flatness 0.04mm (allowable 0.01) gave a wrong measurement datum

Root Cause

[Mechanism] Insufficient scraping and unsuitable support points left the platform uneven.
[Calculation] A flatness of 0.04 made the Z error of the measuring points 0.04 against the 0.01 allowable, so parts were wrongly judged out of tolerance.
[Design Omission] No three-point support or flatness scraping was done; this design flaw caused the measurement errors.

Correct Solution

1) Support the platform at three points and level it;
2) Scrape the flatness to ≤0.01;
3) Require at least 25 contact points per 25×25;
4) Inspect the flatness;
5) Keep the environment at 20±1℃;
6) Re-inspect periodically;
7) Avoid concentrated local loading;
8) Bring flatness into the metrology inspection.