Excessive Cylinder Head Valve Seat Position Causes Blow-By

E43-229 · Geometrical Tolerance Errors · Diesel Engine Cylinder Head Valve Seat · ★★★

Problem Symptom

Valve seat position Φ0.3mm (allowable Φ0.1) left the seal loose and the gas leaked

Root Cause

[Mechanism] Zero point drift on the machining center shifted the seat rings.
[Calculation] A position tolerance of Φ0.3 shifted the seat ring by 0.3 against the 0.1 sealing band, so gas leaked.
[Design Omission] No on-line tool setting was performed and the position tolerance was not inspected; this design flaw caused the leak.

Correct Solution

1) Use on-line tool setting on the machining center;
2) Inspect the position tolerance ≤Φ0.1;
3) Unify the datum on the main dowel holes;
4) Measure the first piece on a CMM;
5) Press the seat rings hydraulically;
6) Perform a gas tightness leak test;
7) Re-check the torques;
8) Bring position tolerance into the mandatory inspection list.

Checklist

References

GB/T 1182-2018 Geometrical Tolerances