Excessive Coaxiality of Robot Joint Bearing Seats Causes Positioning Error

E43-231 · Geometrical Tolerance Errors · Six-Axis Robot Joint Arm · ★★★

Problem Symptom

Coaxiality of the two joint bearing seats 0.05mm (allowable 0.015) caused end-effector positioning error

Root Cause

[Mechanism] The datum transfer between two operation sequences left the two seats non-coaxial.
[Calculation] A coaxiality of 0.05 deflected the arm by 0.05, amplified to an end-effector error of 0.05×800/60≈0.67mm.
[Design Omission] The two bearing holes were not bored in one setup; this design flaw caused the positioning error.

Correct Solution

1) Bore both bearing holes in one setup;
2) Inspect coaxiality ≤0.015;
3) Unify the datum;
4) Age the arm after welding;
5) Match the gearbox;
6) Calibrate the end-effector accuracy;
7) Run unloaded to verify;
8) Bring coaxiality into the process specification.