E43-232 · Geometrical Tolerance Errors · Gearbox Housing Split Face · ★★
Split face flatness 0.05mm (allowable 0.02) let oil seep through the joint face
[Mechanism] Planer clamping left the split face uneven.
[Calculation] A flatness of 0.05 opened a joint gap of 0.05 against the 0.02 allowable, so oil seeped out.
[Design Omission] The split face was not scraped and its flatness was not inspected; this design flaw caused the leakage.
1) Scrape the split face to flatness ≤0.02;
2) Require at least 12 contact points per 25×25;
3) Apply sealant;
4) Tighten the bolts with even force;
5) Perform a leak test under pressure;
6) Keep the oil return grooves clear;
7) Re-inspect periodically;
8) Bring flatness into the assembly inspection.
GB/T 1182-2018 Geometrical Tolerances