Excessive Turbine Rotor Coupling Coaxiality Causes Heavy Vibration

E43-244 · Geometrical Tolerance Errors · Steam Turbine Rotor Coupling Section ∅300 · ★★★

Problem Symptom

Coaxiality of the two coupling ends 0.08mm (allowable 0.03) caused heavy machine vibration

Root Cause

[Mechanism] The rotor was machined in sections from non-coincident datums.
[Calculation] A coaxiality of 0.08 offset the coupling by 0.08 against the 0.03 allowable, so the vibration exceeded the limit and tripped the machine.
[Design Omission] No joint inspection and alignment were done and the coaxiality was not inspected; this design flaw caused the heavy vibration.

Correct Solution

1) Machine the coupling section in one setup;
2) Inspect coaxiality ≤0.03;
3) Laser-align on site;
4) Dynamically balance the rotor to G2.5;
5) Tighten the coupling bolts with even force;
6) Warm up and run up the speed to check the vibration;
7) Re-check the offset;
8) Bring coaxiality into the final assembly inspection.

Checklist

References

GB/T 1182-2018 Geometrical Tolerances