Problem Symptom

Piston rod straightness 0.05 over the full length (allowable 0.02) made the motion bind

Root Cause

[Mechanism] Insufficient straightening and bending during storage.
[Calculation] A straightness of 0.05 offset the rod by 0.05 against the 0.02 seal clearance, so it bound.
[Design Omission] The rod was not straightened and the straightness was not inspected; this design flaw caused the binding.

Correct Solution

1) Straighten the piston rod to straightness ≤0.02;
2) Use the center holes as the datum;
3) Rough and finish turn in one setup;
4) Inspect the straightness;
5) Hard-chrome the surface;
6) Match the seal;
7) Verify smooth motion in a trial run;
8) Bring straightness into the process specification.