Excessive Injection Moulding Tie Bar Cylindricity Causes Uneven Clamping

E43-246 · Geometrical Tolerance Errors · Injection Moulding Machine Tie Bar ∅120×1600 · ★★★

Problem Symptom

Tie bar cylindricity 0.03mm (allowable 0.012) made the clamping force uneven and produced flash

Root Cause

[Mechanism] Taper from large-scale grinding made the cross-sections unequal.
[Calculation] A cylindricity of 0.03 made the four tie bar extension difference 0.03×1600/200000≈0.00024, which is uneven.
[Design Omission] The grinding bar was not verified and the cylindricity was not inspected; this design flaw caused the uneven clamping.

Correct Solution

1) Add support to the grinding bar;
2) Inspect cylindricity ≤0.012;
3) Group the four tie bars to equal length;
4) Use separate rough and fine grinding passes;
5) Preload the nuts with even force;
6) Perform a clamping trial press;
7) Re-check the extension;
8) Bring cylindricity into the process specification.

Checklist

References

GB/T 1182-2018 Geometrical Tolerances

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »