E43-249 · Geometrical Tolerance Errors · Gantry Planer Table 3000 · ★★
Parallelism between the table and the crossbeam 0.06mm (allowable 0.02) tilted the planed surface
[Mechanism] Insufficient scraping during assembly left the table face non-parallel to the crossbeam.
[Calculation] A parallelism of 0.06 gave a height difference of 0.06 across the 3000 width, so the planed surface tilted 0.00002rad.
[Design Omission] No equal-height scraping was done; this design flaw caused the tilted surface.
1) Scrape and level the table face and the crossbeam to equal height;
2) Inspect parallelism ≤0.02;
3) Level the machine feet;
4) Plane a large face as a test and check flatness;
5) Tighten with even force;
6) Re-verify periodically;
7) Re-measure after heavy cutting;
8) Bring parallelism into the acceptance criteria.
GB/T 1182-2018 Geometrical Tolerances