Excessive Wind Turbine Mainshaft Total Runout Exceeds the Vibration Limit

E43-250 · Geometrical Tolerance Errors · Wind Turbine Mainshaft ∅400×2500 · ★★★

Problem Symptom

Mainshaft total runout 0.1mm (allowable 0.04) pushed the machine vibration beyond the limit

Root Cause

[Mechanism] The eccentricity of each section combined with bending added up into the total runout.
[Calculation] A total runout of 0.1 shifted the center of mass by 0.05 and the residual unbalance exceeded G4, tripping the machine.
[Design Omission] The shaft was not straightened and the total runout was not inspected; this design flaw caused the excess vibration.

Correct Solution

1) Straighten the mainshaft to a total runout ≤0.04;
2) Unify the datum on the two center holes;
3) Rough and finish turn in one setup;
4) Dynamically balance to G4;
5) Inspect the total runout;
6) Remove material and add counterweights;
7) Verify the unloaded vibration ≤2.8;
8) Bring total runout into the final assembly inspection.

Checklist

References

GB/T 1182-2018 Geometrical Tolerances