Knowledge Base › Tolerance and Fit Error Case › Pump Body Multi-Chamber Concentricity Accumulation

Pump Body Multi-Chamber Concentricity Accumulation

E43-458 · Dimensional-Chain Accumulation · Pump body 3-chamber concentricity designed φ0.02, measured φ0.11 · ★★

Problem Description

Accumulated multi-chamber machining made concentricity φ0.11 out of tolerance and reduced volumetric efficiency.

Root Cause

[Mechanism] Datum transfer when chambers were machined in separate set-ups accumulated so the closed loop (concentricity) went out of tolerance.
[Calculation] T0=√(3×0.06²)=0.1, 5× the 0.02 allowance.
[Design Omission] Chambers not bored in one set-up; design defect → concentricity out of tolerance.

Corrective Solution

1) Bore all chambers in one set-up;
2) Allocate each chamber tolerance per T0;
3) Unify the datum;
4) Check concentricity with a mandrel;
5) Selective matching by measurement;
6) Leave grinding stock;
7) Coordinate check;
8) First-article concentricity measured ≤φ0.02.

Checklist

Reference

GB/T 3216-2016 Rotodynamic pumps — Hydraulic performance acceptance tests