E43-465 · Dimensional-Chain Accumulation · Dividing head indexing designed 30°±10″, measured ±55″ after 5 loops · ★★★
Multi-loop dimensional-chain accumulation made indexing 55″ out of tolerance and workpiece angles off.
[Mechanism] The worm-gear + indexing-disk dimensional chain accumulated, so the closed loop (indexing) went out of tolerance.
[Calculation] T0=√(5×0.025²)=0.056°≈55″, 5.5× the 10″ allowance.
[Design Omission] Accumulation and match-machining not controlled; design defect → indexing out of tolerance.
1) Improve worm-gear accuracy;
2) Match-machine each loop per T0/√5;
3) Unify the datum;
4) Statistical check;
5) Selective matching by measurement;
6) Leave grinding stock;
7) Dividing-head instrument check;
8) First-article indexing measured ≤10″.
GB/T 5847-2004 Dimensional chain — Calculation method