E43-466 · Dimensional-Chain Accumulation · Injection mold die height designed 300±0.05, measured 300.4 after 4 plates · ★★
Accumulated mold-plate thicknesses made die height 0.4mm out of tolerance, causing flash.
[Mechanism] Multi-plate thickness dimensional chain accumulated, so the closed loop (die height) went out of tolerance.
[Calculation] T0=ΣTi=4×0.1=0.4, 8× the 0.05 allowance.
[Design Omission] No adjustment or match-machining; design defect → die-height deviation.
1) Provide a shim to absorb accumulation;
2) Match-grind each plate per T0/√4;
3) Unify the datum;
4) Statistical check;
5) Selective matching by measurement;
6) Leave grinding stock;
7) Height gauge check;
8) First-article die height measured ≤0.05.
GB/T 8845-2017 Stamping dies — Terminology