📚 Technical Articles

Knowledge Base › Tolerance and Fit Error Case › Robot Multi-Joint Accumulation

Robot Multi-Joint Accumulation

E43-471 · Dimensional-Chain Accumulation · Robot end position designed ±0.05, measured ±0.3 after 6 joints · ★★★

Problem Description

Multi-joint error accumulation made end position 0.3mm out of tolerance, shifting positioning.

Root Cause

[Mechanism] Multi-joint motion-error dimensional chain accumulated, so the closed loop (end position) went out of tolerance.
[Calculation] T0=√(6×0.12²)=0.3, 6× the 0.05 allowance.
[Design Omission] Per-joint accuracy not allocated; design defect → end-position out of tolerance.

Corrective Solution

1) Allocate each joint accuracy per T0/√6;
2) Improve reducer accuracy;
3) Calibration compensation;
4) Statistical check;
5) Selective matching by measurement;
6) Leave adjustment allowance;
7) Laser tracker check;
8) First-article end position measured ≤0.05.

Checklist

Reference

GB/T 12642-2012 Industrial robots — Performance criteria and related testing