MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Tolerance and Fit Error Case › CMM Multi-Axis Accumulation

CMM Multi-Axis Accumulation

E43-472 · Dimensional-Chain Accumulation · CMM Z-direction designed ±0.005, measured ±0.02 after 3 axes · ★★★

Problem Description

Multi-axis error accumulation made measurement 0.02mm out of tolerance and readings unstable.

Root Cause

[Mechanism] Multi-axis positioning-error dimensional chain accumulated, so the closed loop (measurement) went out of tolerance.
[Calculation] T0=√(3×0.012²)=0.02, 4× the 0.005 allowance.
[Design Omission] Per-axis accuracy not allocated; design defect → measurement out of tolerance.

Corrective Solution

1) Allocate each axis accuracy per T0/√3;
2) Linear-scale closed-loop compensation;
3) Calibrate each axis;
4) Statistical check;
5) Selective matching by measurement;
6) Leave adjustment allowance;
7) Calibrate with a standard artifact;
8) First-article error measured ≤0.005.

Checklist

Reference

GB/T 16857.2-2017 Coordinate measuring machines (CMM) — Acceptance and re-verification tests

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL