MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Tolerance and Fit Error Case › Gear Pump Multi-Part Trapped-Oil Accumulation

Gear Pump Multi-Part Trapped-Oil Accumulation

E43-488 · Dimensional-Chain Accumulation · Gear pump axial clearance designed 0.03~0.06, measured 0.15 after 3 parts · ★★

Problem Description

[Calculation] T0=√(4×0.125²)=0.25, exceeding the 0.2 upper limit.

Root Cause

[Mechanism] Multi-part axial dimensional chain accumulated, so the closed loop (clearance) went out of tolerance and trapped oil.
[Calculation] T0=ΣTi=3×0.05=0.15, 2.5× the 0.06 upper limit.
[Design Omission] No adjustment or match-machining; design defect -> clearance out of tolerance.

Corrective Solution

1) Provide a shim to absorb accumulation;
2) Match-machine each part per T0/√3;
3) Unify the datum;
4) Statistical check;
5) Selective matching by measurement;
6) Leave grinding stock;
7) Clearance gauge check;
8) First-article clearance measured 0.03~0.06.

Checklist

Reference

GB/T 23582-2009 Gear pumps

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL