Knowledge Base › Tolerance and Fit Error Case › Fixture Clamping Height Accumulation

Fixture Clamping Height Accumulation

E43-491 · Dimensional-Chain Accumulation · Fixture clamping height designed 80±0.05, measured 80.4 after 4 parts · ★★

Problem Description

Locating + clamping-element accumulation made clamping height 0.4mm out of tolerance, shifting the workpiece.

Root Cause

[Mechanism] Multi-part height dimensional chain accumulated, so the closed loop (clamping height) went out of tolerance.
[Calculation] T0=ΣTi=4×0.1=0.4, 8× the 0.05 allowance.
[Design Omission] No adjustment or match-machining; design defect → clamping-height deviation.

Corrective Solution

1) Provide a shim to absorb accumulation;
2) Match-machine each part per T0/√4;
3) Unify the datum;
4) Statistical check;
5) Selective matching by measurement;
6) Leave grinding stock;
7) Height gauge check;
8) First-article clamping height measured ≤0.05.

Checklist

Reference

GB/T 5847-2004 Dimensional chain — Calculation method