E43-495 · Dimensional-Chain Accumulation · Crankshaft throw spacing designed 120±0.05, measured 120.3 after 4 throws · ★★
Multi-throw machining accumulation made throw spacing 0.3mm out of tolerance, shifting dynamic balance.
[Mechanism] Multi-throw phase chain accumulated, so the closed loop (throw spacing) went out of tolerance.
[Calculation] T0=ΣTi=4×0.075=0.3, 6× the 0.05 allowance.
[Design Omission] No adjustment or match-machining; design defect → throw spacing out of tolerance.
1) Provide an eccentric fixture to absorb accumulation;
2) Match-machine each throw per T0/√4;
3) Unify the datum;
4) Statistical check;
5) Selective matching by measurement;
6) Leave grinding stock;
7) Throw-spacing gauge check;
8) First-article throw spacing measured ≤0.05.
GB/T 5847-2004 Dimensional chain — Calculation method