Large-Unit Anchor-Bolt Accumulation

E43-500 · Dimensional-Chain Accumulation · Unit anchor spacing designed 6000±1, measured 6012 after 8 anchors · ★★★

Problem Description

Multi-anchor installation chain accumulation made anchor spacing 12mm out of tolerance and broke alignment.

Root Cause

[Mechanism] Multi-anchor installation chain accumulated, so the closed loop (anchor spacing) went out of tolerance and broke alignment.
[Calculation] T0=ΣTi=8×1.5=12, 12× the 1 allowance.
[Design Omission] No adjustment or unified datum; design defect → anchor spacing out of tolerance.

Corrective Solution

1) Provide adjustable shim plates to absorb accumulation;
2) Match-machine each anchor per T0/√8;
› Milling Fixture Hole-Position Accumulation
4) Statistical check;
5) Selective matching by measurement;
6) Leave grinding stock;
7) Laser alignment check;
8) First-article anchor-bolt spacing measured ≤1.