Design Datum Misaligned with Process Datum Causes Uneven Wall Thickness

E43-020 · Non-coincident Datums · Housing Machining · ★★

Problem Symptom

Wall thickness variation 2.5mm (allowable 1.0); casting stress cracking; 12 parts scrapped per month

Root Cause

[Datum Misalignment] The design used the centerline as datum while the process located from the raw casting face; the 1.5mm offset was replicated into the wall thickness.
[Unevenness] The 1.5mm overcut on one side brought the thickness variation to 2.5mm, sharply reducing local stiffness and creating stress concentration.
[Design Omission] No unified process datum was established and no datum transfer tolerance was specified, so the machining allowance was distributed unevenly.

Correct Solution

1) Establish a unified process datum (one face, two holes) to prevent non-coincident datums;
2) Specify a datum transfer tolerance ≤0.5 to control accumulated error;
3) Distribute the raw casting allowance evenly to prevent distortion;
4) Inspect for cracks by NDT after rough machining to prevent them spreading;
5) Spot-check wall thickness on a CMM for monitoring;
6) Define the locating datum clearly in the process sheet to prevent mix-ups;
7) Add process bosses for auxiliary location to raise rigidity;
8) Bring datum transfer into the process review.

Checklist

References

GB/T 1182-2018 Geometrical Product Specifications (GPS) — Geometrical Tolerances