Measurement Datum Different from Assembly Datum Causes Clearance Out of Tolerance

E43-021 · Non-coincident Datums · Flange Disc Inspection · ★

Problem Symptom

Parts passed inspection but assembly clearance exceeded 0.06mm, causing a 30% matching rework rate

Root Cause

[Datum Mismatch] Inspection used face A as the datum while assembly located from face B; the A/B parallelism of 0.05 was not controlled.
[Out of Tolerance] The datum transfer error went straight into the clearance: a measured 0.02 became an actual 0.07.
[Design Omission] The design, process and inspection datums should be unified and specified, and the parallelism of face B was not controlled.

Correct Solution

1) Unify the design, process and inspection datums;
2) Specify A/B face parallelism ≤0.02;
3) Use the same datum face for inspection and assembly;
4) Establish matching and grouping tolerance bands;
5) Keep gauge calibration consistent;
6) Verify assembly on the first piece;
7) Maintain process capability CPK≥1.33;
8) Bring datum unification into drawing review.

Checklist

References

GB/T 4249-2018 Geometrical Product Specifications (GPS) — Fundamental Principles of Tolerance