Wrong Datum Selection for the Hole Group Causes Position Shift

E43-022 · Non-coincident Datums · Multi-Hole Connection Plate · ★★

Problem Symptom

The hole group shifted 0.10mm relative to its theoretical position; the bolts would not pass through; 20 parts reworked per month

Root Cause

[Wrong Datum] The hole group should share datum B but C was used by mistake, and the 0.08 position tolerance between C and B added to the error.
[Shift] The datum transfer shifted the whole group by 0.08, while the clearance of an M10 bolt is only 0.05, so the bolts could not be inserted.
[Design Omission] A grouped datum was not used and no position tolerance frame was specified, leaving the datum system confused.

Correct Solution

1) Use the unified grouped datum B for the hole group to prevent accumulation;
2) Specify the position tolerance frame Φ0.05 to control hole positions;
3) Locate the drilling jig from datum B to guarantee consistency;
4) Machine multiple holes in one CNC setup to prevent setup-to-setup position shifts;
5) Measure hole positions on a CMM on the first piece to verify;
6) Make the datum reference frame explicit on the drawing to prevent misreading;
7) Spot-check position tolerance during production for monitoring;
8) Bring the datum system into drawing review.

Checklist

References

GB/T 1182-2018 Geometrical Product Specifications (GPS) — Geometrical Tolerances