Machining Datum Not Coincident with Design Datum Causes Cumulative Offset

E43-066 · Non-coincident Datums · Bed Guideway · ★★★

Problem Symptom

Machining used the raw casting face as datum instead of the design centerline, giving a cumulative offset of 0.15 and guideway parallelism out of tolerance

Root Cause

[Non-coincident Datum] The design datum was the centerline, but machining mistakenly used the raw casting face, giving a datum shift Δ=0.15.
[Cumulative Offset] The non-coincident datum error stacked up, pushing guideway parallelism beyond 0.08/1000.
[Design Omission] A unified design datum should have been specified with the workpiece centerline used for location, but no datum transfer calculation was made.

Correct Solution

1) Unify the design datum to prevent non-coincident datum error;
2) Locate from the centerline to guarantee symmetry;
3) Calculate the datum transfer error to prevent accumulation;
4) Provide datum blocks on the fixture for consistent alignment;
5) Keep parallelism ≤0.02/1000 to guarantee fit;
6) Inspect the first piece on a CMM;
7) Keep process datums consistent to prevent mix-ups;
8) Re-mill out-of-specification parts.

Checklist

References

GB/T 1182-2018 Geometrical Tolerances

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL