E43-066 · Non-coincident Datums · Bed Guideway · ★★★
Machining used the raw casting face as datum instead of the design centerline, giving a cumulative offset of 0.15 and guideway parallelism out of tolerance
[Non-coincident Datum] The design datum was the centerline, but machining mistakenly used the raw casting face, giving a datum shift Δ=0.15.
[Cumulative Offset] The non-coincident datum error stacked up, pushing guideway parallelism beyond 0.08/1000.
[Design Omission] A unified design datum should have been specified with the workpiece centerline used for location, but no datum transfer calculation was made.
1) Unify the design datum to prevent non-coincident datum error;
2) Locate from the centerline to guarantee symmetry;
3) Calculate the datum transfer error to prevent accumulation;
4) Provide datum blocks on the fixture for consistent alignment;
5) Keep parallelism ≤0.02/1000 to guarantee fit;
6) Inspect the first piece on a CMM;
7) Keep process datums consistent to prevent mix-ups;
8) Re-mill out-of-specification parts.
GB/T 1182-2018 Geometrical Tolerances