Non-coincident Measurement Datum Causes False Out-of-Tolerance Judgement

E43-067 · Non-coincident Datums · Gearbox Housing · ★★

Problem Symptom

Measurement used the top face instead of the design hole pattern datum, falsely rejecting parts and causing 30 parts to be reworked

Root Cause

[Non-coincident Datum] The design used the bore as datum, but measurement mistakenly used the top face, and the datum shift made the reading off by 0.08.
[False Judgement] The non-coincident datum meant the measured value included the shift error, so conforming parts were judged scrap.
[Design Omission] The measurement datum should be specified to match the design datum with tolerances called out, but the datums were never unified.

Correct Solution

1) Unify the measurement datum with the design datum to prevent false judgements;
2) Locate from the hole pattern datum;
3) Remove the datum shift error so the true value is preserved;
4) Unify the inspection fixtures to prevent measurement differences;
5) Fix the CMM programme to remove human variation;
6) Compare the first piece against the design value;
7) Re-check false judgements to prevent wrongly scrapping parts;
8) Re-measure out-of-specification parts for confirmation.