E43-508 · Datum Non-Coincidence · A member tack-welded off layout lines while designed to use the jig datum, position 0.8 over tolerance · ★★

Problem Description

The layout-line datum did not coincide with the welding jig datum, giving member position error 0.8mm.

Root Cause

[Mechanism] The layout-line datum and the jig datum do not coincide, so line error feeds into position.
[Calculation] Datum non-coincidence error = line error 0.8, 1.6× the assembly tolerance of 0.5.
[Design Omission] The jig was not used as the unified datum; design defect → position out of tolerance.

Corrective Solution

1) Use the welding jig as the unified datum;
2) Drop layout lines; locate on the jig;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) First-article jig inspection;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article position measured ≤0.5.

Checklist

Reference

GB/T 50205-2020 Standard for acceptance of construction quality of steel structures