E43-509 · Datum Non-Coincidence · An injection mold located on the parting plane while designed to use the product datum, mold shift 0.1 · ★★
The mold parting-plane datum did not coincide with the product design datum, giving 0.1mm mold-shift flash.
[Mechanism] The parting-plane datum does not coincide with the design datum, so the cavity position shifts.
[Calculation] Datum non-coincidence error = parting-plane-to-product error 0.1, 3.3× the tolerance of 0.03.
[Design Omission] The cavity was not built to the product datum; design defect → mold shift.
1) Build the cavity to the product datum;
2) Add datum pins on the parting plane;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) First-article trial-mold inspection;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article mold shift measured ≤0.03.
GB/T 8845-2017 Stamping dies — Terminology