Knowledge Base › Tolerance and Fit Error Case › Fixture Bottom-Face Alignment Datum Mismatch

Fixture Bottom-Face Alignment Datum Mismatch

E43-510 · Datum Non-Coincidence · A fixture located on the bottom face while designed to use the guide hole, position 0.06 over tolerance · ★★

Problem Description

The fixture bottom-face datum did not coincide with the design guide-hole datum, giving workpiece position error 0.06mm.

Root Cause

[Mechanism] The bottom face and guide-hole datums do not coincide, so bottom-thickness error feeds in.
[Calculation] Datum non-coincidence error = bottom-face-to-guide-hole error 0.06, 3× the tolerance of 0.02.
[Design Omission] The design guide hole was not used as the datum; design defect → workpiece position out of tolerance.

Corrective Solution

1) Use the design guide hole as the locating datum;
2) Redesign the fixture locating face;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) First-article inspection;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article position measured ≤0.02.