E43-511 · Datum Non-Coincidence · A shaft turned in a chuck while designed to use center holes, eccentricity 0.05 · ★★
The chuck clamping datum did not coincide with the designed center-hole datum, giving eccentricity 0.05mm after turning.
[Mechanism] Chuck clamping and center-hole datums do not coincide, so chuck run-out feeds into eccentricity.
[Calculation] Datum non-coincidence error = chuck run-out 0.05, 2.5× the roundness tolerance of 0.02.
[Design Omission] Center holes were not used as the datum; design defect → eccentricity out of tolerance.
1) Switch to center-hole locating for turning;
2) Match a dead center to the chuck;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) First-article eccentricity measurement;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article eccentricity measured ≤0.02.
GB/T 1182-2018 GPS — Geometrical tolerancing (form, orientation, location and run-out)