E43-512 · Datum Non-Coincidence · A part slot-milled on a side face while designed to use the centerline, slot offset 0.12 · ★★
The side-face locating datum did not coincide with the design centerline, giving slot offset 0.12mm.
[Mechanism] The side face and centerline datums do not coincide, so side-to-center dimension error feeds into slot position.
[Calculation] Datum non-coincidence error = side-to-center error 0.12, 3× the tolerance of 0.04.
[Design Omission] The centerline was not used as the datum; design defect → slot offset.
1) Use the centerline (trammed in) as the datum;
2) Add a centering feature;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) First-article slot-position inspection;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article slot offset measured ≤0.04.
GB/T 1182-2018 GPS — Geometrical tolerancing (form, orientation, location and run-out)