Knowledge Base › Tolerance and Fit Error Case › Grinder End-Face vs Bore-Axis Datum Mismatch

Grinder End-Face vs Bore-Axis Datum Mismatch

E43-513 · Datum Non-Coincidence · A part internal-bore ground on an end face while designed to use the bore axis, coaxiality 0.04 · ★★

Problem Description

The end-face locating datum did not coincide with the design bore-axis datum, giving coaxiality 0.04mm after grinding.

Root Cause

[Mechanism] The end face and bore-axis datums do not coincide, so end-face run-out feeds into coaxiality error.
[Calculation] Datum non-coincidence error = end-face run-out 0.04, 4× the coaxiality tolerance of 0.01.
[Design Omission] The bore axis was not used as the datum; design defect → coaxiality out of tolerance.

Corrective Solution

1) Use the bore axis as the locating datum;
2) Control end-face run-out tightly;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) First-article coaxiality measurement;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article coaxiality measured ≤0.01.