Knowledge Base › Tolerance and Fit Error Case › Boring Machine Two-Hole Different-Datum Mismatch

Boring Machine Two-Hole Different-Datum Mismatch

E43-514 · Datum Non-Coincidence · A housing bored bore A first then re-datummed to bore B, center distance 0.09 over tolerance · ★★★

Problem Description

Two bores were machined on different datums in separate set-ups, giving center-distance error 0.09mm.

Root Cause

[Mechanism] The datum holes of the two set-ups do not coincide, so the hole-to-hole dimension error feeds into center distance.
[Calculation] Datum non-coincidence error = two-hole link dimension error 0.09, 3× the tolerance of 0.03.
[Design Omission] The two bores were not bored in one set-up; design defect → center distance out of tolerance.

Corrective Solution

1) Bore both holes in one set-up;
2) Unify on one face and two holes as the datum;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) First-article CMM check;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article center distance measured ≤0.03.

Checklist

Reference

GB/T 10095.1-2008 Cylindrical gears — Accuracy system — Part 1