E43-515 · Datum Non-Coincidence · A part measured first at origin A then origin B, coordinate offset 0.2 · ★★

Problem Description

Measurement origin was switched between set-ups, giving coordinate offset 0.2mm and a misjudgment.

Root Cause

[Mechanism] The two measurement origins do not coincide, so the origin link dimension error feeds into the coordinate.
[Calculation] Datum non-coincidence error = two-origin link error 0.2, 20× the measurement tolerance of 0.01.
[Design Omission] A unified fixed origin was not set; design defect → coordinate offset.

Corrective Solution

1) Fix a unified measurement origin;
2) Build a consistent coordinate-system datum;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) First-article re-measurement;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article coordinate measured ≤0.01.