Bearing End-Face Datum Mismatch

E43-524 · Datum Non-Coincidence · A bearing located on the end face while designed to use the shaft center as datum, runout 0.02 over tolerance · ★★

Problem Description

The end-face location and the design shaft-center datum do not coincide, leaving the rotational runout 0.02mm out of tolerance.

Root Cause

[Mechanism] The end face and the shaft-center datum do not coincide, so end-face runout feeds into rotational runout.
[Calculation] Datum non-coincidence error = end-face runout 0.02, 2.5× the runout tolerance of 0.008.
[Design Omission] The shaft center was not used as the datum; design defect → runout out of tolerance.

Corrective Solution

1) Use the shaft center (inner bore) as the locating datum;
2) Control end-face run-out tightly;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) First-article run-out measurement;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article runout measured ≤0.008.

Checklist

Reference

GB/T 307.3-2017 Rolling bearings — General technical specifications