Coupling Flange Datum Mismatch

E43-525 · Datum Non-Coincidence · A coupling located on the flange face while designed to use the hole datum, 0.1 over tolerance · ★★

Problem Description

The flange-face datum and the design hole datum do not coincide, leaving the alignment 0.1mm out of tolerance.

Root Cause

[Mechanism] The flange face and the hole datum do not coincide, so the face-to-hole dimension error feeds in.
[Calculation] Datum non-coincidence error = face-to-hole error 0.1, 3.3× the alignment tolerance of 0.03.
[Design Omission] The hole was not used as the datum; design defect → alignment out of tolerance.

Corrective Solution

1) Use the design hole as the locating datum;
2) Provide tooth-alignment marks / dowel pins;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) Laser-align the first article;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article alignment measured ≤0.03.

Checklist

Reference

GB/T 1182-2018 GPS — Geometrical tolerancing (form, orientation, location and run-out)