E43-528 · Datum Misalignment · Worm wheel located on the outside diameter while the design references the throat, causing a 0.08 overshoot · ★★
The outside-diameter datum does not coincide with the design throat, so the meshing center exceeds tolerance by 0.08mm.
[Mechanism] The outside-diameter datum does not coincide with the throat, so OD eccentricity is carried into the throat position.
[Calculation] The datum misalignment error is an OD eccentricity of 0.08, which is 2.7 times the center allowance of 0.03.
[Design Omission] The throat is not used as the datum; this design flaw leads to meshing out-of-tolerance.
1) Use the throat (hobbing) as the locating datum;
2) Control OD eccentricity;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) Measure the center distance on the first article;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article center measured ≤0.03.
GB/T 10089-2018 Cylindrical worm gearing — Accuracy