E43-529 · Datum Misalignment · Cam located on the end face while the design references the lift-start point, causing a 0.1 overshoot · ★★

Problem Description

The end-face datum does not coincide with the design lift-start point, so the lift deviates by 0.1mm.

Root Cause

[Mechanism] The end-face datum does not coincide with the lift-start point, so end-face runout is carried into the lift.
[Calculation] The datum misalignment error is an end-face runout of 0.1, which is 3.3 times the lift allowance of 0.03.
[Design Omission] The lift-start point is not used as the datum; this design flaw leads to lift out-of-tolerance.

Corrective Solution

1) Use the lift-start point as the locating datum;
2) Keep end-face runout small;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) Measure lift on the first article;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article lift measured ≤0.03.

Checklist

Reference

GB/T 1182-2018 GPS — Geometrical tolerancing (form, orientation, location and run-out)