E43-530 · Datum Misalignment · Indexing table set to an arbitrary position as zero while the design uses the keyway as zero, causing a 5° overshoot · ★★
The zero-position datum does not coincide with the design keyway, causing a 5° indexing deviation and misassembly.
[Mechanism] The zero-position datum does not coincide with the keyway datum, so the phase offset is carried into the indexing.
[Calculation] The datum misalignment error is a 5° phase offset, which is 5 times the indexing allowance of 1°.
[Design Omission] The keyway is not used as the zero position; this design flaw leads to indexing out-of-tolerance.
1) Use the design keyway as the zero-position datum;
2) Provide a zero-position pin;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) Measure indexing on the first article;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article indexing measured ≤1°.
GB/T 1182-2018 GPS — Geometrical tolerancing (form, orientation, location and run-out)