E43-531 · Datum Misalignment · Fixture located on the side face while the design references the bottom face, causing a 0.07 overshoot · ★★
The side-face datum does not coincide with the design bottom face, so the workpiece height difference is 0.07mm.
[Mechanism] The side-face datum does not coincide with the bottom face, so the side-to-height dimension error is carried in.
[Calculation] The datum misalignment error is a side-to-height error of 0.07, which is 3.5 times the allowance of 0.02.
[Design Omission] The bottom face is not used as the datum; this design flaw leads to height-difference out-of-tolerance.
1) Use the design bottom face as the locating datum;
2) Redesign the locating surface;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) First-article inspection;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article height measured ≤0.02.
GB/T 1182-2018 GPS — Geometrical tolerancing (form, orientation, location and run-out)