Knowledge Base › Tolerance and Fit Error Case › Gauge-to-GO-End Datum Misalignment

Gauge-to-GO-End Datum Misalignment

E43-532 · Datum Misalignment · Gauge referenced to the GO end while the design references the NO-GO end, causing a 0.03 misjudgment · ★★

Problem Description

The gauge datum does not coincide with the design requirement, causing acceptable parts to be misjudged by 0.03mm.

Root Cause

[Mechanism] The gauge GO-end datum does not coincide with the design NO-GO-end datum, so the datum offset is carried in.
[Calculation] The datum misalignment error is a GO-to-NO-GO end distance error of 0.03, which is 3 times the gauge allowance of 0.01.
[Design Omission] The design NO-GO end is not used as the datum; this design flaw leads to misjudgment.

Corrective Solution

1) Reference the gauge to the design NO-GO end;
2) Hold the GO-to-NO-GO end distance accurately;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) Re-measure the first article against the design datum;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article measured ≤0.01.

Checklist

Reference

GB/T 1182-2018 GPS — Geometrical tolerancing (form, orientation, location and run-out)