E43-534 · Datum Misalignment · Crankshaft located on the main journal while the design references the crankpin journal, causing a 0.06 overshoot · ★★★
The main-journal datum does not coincide with the design crankpin journal, so the crankpin position exceeds tolerance by 0.06mm.
[Mechanism] The main-journal datum does not coincide with the crankpin journal, so main-journal runout is carried into the pin position.
[Calculation] The datum misalignment error is a main-journal runout of 0.06, which is 3 times the pin-position allowance of 0.02.
[Design Omission] The crankpin journal is not used as the datum; this design flaw leads to pin-position out-of-tolerance.
1) Use the crankpin journal as the locating datum;
2) Control main-journal runout;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) Measure pin position on the first article;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article pin position measured ≤0.02.
GB/T 1182-2018 GPS — Geometrical tolerancing (form, orientation, location and run-out)