E43-540 · Datum Misalignment · Robot referenced to its body while the design references the world frame, causing a 2mm overshoot · ★★★
The body datum does not coincide with the design world frame, so the end-effector position deviates by 2mm.
[Mechanism] The body coordinate frame does not coincide with the world frame, so the origin offset is carried to the end effector.
[Calculation] The datum misalignment error is a 2mm origin offset, which is 40 times the repeatability of 0.05.
[Design Omission] The world frame is not calibrated; this design flaw leads to end-effector out-of-tolerance.
1) Calibrate the world coordinate frame;
2) Establish a datum origin;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) Laser-track the first article;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article end position measured ≤0.05.
GB/T 12642-2012 Industrial robots — Performance criteria and related testing