Measurement-to-Reference Datum Misalignment

E43-541 · Datum Misalignment · Measurement referenced to the surface plate while the design uses the workpiece datum, causing a 0.04 overshoot · ★★

Problem Description

The plate reference datum does not coincide with the workpiece design datum, so the measurement deviates by 0.04mm.

Root Cause

[Mechanism] The plate reference does not coincide with the workpiece datum, so the reference-surface error is carried in.
[Calculation] The datum misalignment error is a reference-surface error of 0.04, which is 4 times the measurement allowance of 0.01.
[Design Omission] Measurement is not taken against the workpiece datum; this design flaw leads to measurement out-of-tolerance.

Corrective Solution

1) Measure against the workpiece design datum;
2) Build a workpiece coordinate system;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) First-article re-measurement;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article measured ≤0.01.

Checklist

Reference

GB/T 16857.2-2017 Coordinate measuring machines (CMM) — Acceptance and re-verification tests