E43-542 · Datum Misalignment · Line referenced to the conveyor chain while the design references the station, causing a 1mm overshoot · ★★

Problem Description

The conveyor-chain datum does not coincide with the design station, so the locating position deviates by 1mm.

Root Cause

[Mechanism] The conveyor-chain datum does not coincide with the station, so the accumulated chain-pitch error is carried in.
[Calculation] The datum misalignment error is a 1mm accumulated chain error, which is 5 times the locating allowance of 0.2.
[Design Omission] The station is not used as the datum; this design flaw leads to locating out-of-tolerance.

Corrective Solution

1) Use the station as the locating datum;
2) Provide a stop for locating;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) Measure the locating position on the first article;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article locating measured ≤0.2.

Checklist

Reference

GB/T 1182-2018 GPS — Geometrical tolerancing (form, orientation, location and run-out)