Knowledge Base › Tolerance and Fit Error Case › Vehicle-to-Frame Datum Misalignment

Vehicle-to-Frame Datum Misalignment

E43-543 · Datum Misalignment · Assembly located on the frame while the design references the body datum, causing a 1.5mm overshoot · ★★

Problem Description

The frame datum does not coincide with the body design datum, so the assembly clearance exceeds tolerance by 1.5mm.

Root Cause

[Mechanism] The frame datum does not coincide with the body datum, so frame error is carried into the assembly.
[Calculation] The datum misalignment error is a 1.5mm frame error, which is 3 times the assembly allowance of 0.5.
[Design Omission] The body is not used as the datum; this design flaw leads to assembly out-of-tolerance.

Corrective Solution

1) Assemble against the body design datum;
2) Provide a locating fixture;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) Inspect clearance on the first article;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article clearance measured ≤0.5.

Checklist

Reference

GB/T 1182-2018 GPS — Geometrical tolerancing (form, orientation, location and run-out)

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL