E43-545 · Datum Misalignment · Hull block located on the deck while the design references the keel, causing a 3mm overshoot · ★★★
The deck datum does not coincide with the keel design datum, so the hull line deviates by 3mm.
[Mechanism] The deck datum does not coincide with the keel, so deck error is carried into the hull line.
[Calculation] The datum misalignment error is a 3mm deck error, which is 3 times the hull-line allowance of 1.
[Design Omission] The keel is not used as the datum; this design flaw leads to hull-line out-of-tolerance.
1) Use the keel as the locating datum;
2) Lay out a datum line;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) Laser-inspect the first article;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article hull line measured ≤1.
GB/T 1182-2018 GPS — Geometrical tolerancing (form, orientation, location and run-out)