E43-546 · Datum Misalignment · Motor located on the end shield while the design references the register-spigot datum, causing a 0.05 overshoot · ★★
The end-shield datum does not coincide with the design register-spigot datum, so the rotor air gap deviates by 0.05mm.
[Mechanism] The end-shield datum does not coincide with the register-spigot datum, so the end-shield spigot error is carried into the air gap.
[Calculation] Datum mismatch error = spigot error of 0.05, which is 2.5 times the air-gap allowance of 0.02.
[Design Omission] The register spigot was not used as the datum; this design flaw leads to air-gap overshoot.
1) Use the register spigot as the locating datum;
2) Control the spigot on the end shield;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) Measure the air gap on the first article;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article air gap ≤ 0.02.
GB/T 755-2008 Rotating electrical machines — Rating and performance