Knowledge Base › Tolerance and Fit Error Case › Gear Pump Inlet Datum Misalignment

Gear Pump Inlet Datum Misalignment

E43-547 · Datum Misalignment · Gear pump located on the inlet while the design references the two shaft holes, causing a 0.04 overshoot · ★★

Problem Description

The inlet datum does not coincide with the design shaft-hole datum, so the meshing center exceeds 0.04mm.

Root Cause

[Mechanism] The inlet datum does not coincide with the shaft-hole datum, so the inlet-face error is carried into the center distance.
[Calculation] Datum mismatch error = inlet-face error of 0.04, which is 2 times the center allowance of 0.02.
[Design Omission] The shaft holes were not used as the datum; this design flaw leads to center-distance overshoot.

Corrective Solution

1) Use the shaft holes as the locating datum;
2) Control the inlet-face parallelism;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) Measure the center distance on the first article;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article center distance ≤ 0.02.